Canary Communications
REFERENCE
Product List with Basic Descriptions: Current and Special Order
-Listing of Product Groups by Section Headings-
REV 02/06/04 

Major Product Categories and individual product lines shaded in Green identify soon to be released or Special Order models

  1. Canary Gigabit Ethernet UTP to Fiber, Standalone Converters
  2. Canary Gigabit Fiber to Fiber, Standalone Converters
  3. Canary Fibre Channel, Fiber to Fiber, Standalone Converters
  4. Canarynet 100 Fast Ethernet UTP to Fiber, Standalone Converters
  5. Canarynet 100 Fast Ethernet Fiber to Fiber, Standalone Converters
  6. 10Mbs Standalone Mini-Converters
  7. 2 Port LAN Extenders Standalone, (Two-Port 10/100 Bridges)
  8. Basic Connections! series of Economical "no frills", Standalone Media Conversion
  9. Serial RS to Fiber Optic, Standalone Converters
  10. Serial RS to Ethernet UTP / Fiber Optic, Standalone Converters
  11. Canary ConversionNet 2000 / 0400 Rack Mount Modular Converters
  12. CCN-2000 / 0400 Chassis, 100Mb UTP to Fiber Converter Modules
  13. CCN-2000 / 0400 Chassis, 100 Mb Fiber to Fiber Converter Modules
  14. CCN-2000 / 0400 Chassis, Gigabit UTP to Fiber Converter Modules
  15. CCN-2000 / 0400 Chassis, Gigabit Fiber to Fiber Converter Modules
  16. CCN-2000 / 0400 Chassis, Fibre Channel, Fiber to Fiber Converter Modules
  17. CCN-2000 Chassis, Passive CWDM, MUX/DEMUX Modules
  18. CCN-2000 / 0400 Chassis, Active CWDM, Gigabit UTP to Fiber, Converter Modules
  19. CCN-2000 / O400 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules
  20. CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules
  21. CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 2.125Gigabaud, Fiber to Fiber, Converter Modules
  22. CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, UTP to Fiber, Converter Modules
  23. CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, Fiber to Fiber, Converter Modules
  24. Canarynet 100 CCM-1600 Rack Mount Modular Converter Chassis
  25. CCM-1600 Chassis 10 Mb Converter Modules
  26. CCM-1600 Chassis 100 Mb UTP to Fiber Converter Modules
  27. CCM-1600 Chassis 10/100 Mb Fiber to Fiber Converter Modules
  28. CCM-1600 Chassis Gigabit UTP to Fiber Converter Modules
  29. CCM-1600 Chassis Gigabit Fiber to Fiber Converter Modules
  30. CCM-1600 Chassis, Fibre Channel, Fiber to Fiber Converter Modules
  31. CCM-1600 Chassis, Passive CWDM, MUX/DEMUX Modules
  32. CCM-1600 Chassis, Active CWDM, Gigabit, UTP to Fiber, Converter Modules
  33. CCM-1600 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules
  34. CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules
  35. CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 2.125Gigabaud, Fiber to Fiber, Converter Modules
  36. CCM-1600 Chassis, Active CWDM, 100 Mb, UTP to Fiber, Converter Modules
  37. CCM-1600 Chassis, Active CWDM, 100 Mb, Fiber to Fiber, Converter Modules
  38. Unmanaged 10/100 UTP, Fixed Configuration, Switches
  39. Managed 10/100 UTP / Fiber Optic, Media Converters
  40. Managed 10/100 UTP / Fiber Optic, Fixed-Configuration, Multi-Media Switches
  41. Managed or Smart [Configurable / Modular] 24-Port, 10/100 UTP / Fiber Optic + Gigabit, Multi-Media Switches
  42. WAVEPLEX 2000 2-Channel Wavelength Division Multiplexers [100 Mb Media Converters]
  43. WAVEPLEX 2000 Gigabit, 2-Channel Wavelength Division Multiplexers [Media Converters]
  44. Canarynet 100 Fast Ethernet [MII] Transceivers
  45. 10Mbs AUI Mini-Transceivers
  46. 10Mbs Single Repeater Modules for Discontinued CMR-7020 Series Hubs
  47. Canary Combined Family of CWDM Passive Mux/Demux / OADMs and Active CWDM Converters [from all Product categories]
  48. Canary Rackable/Standalone, Passive (LC) CWDM, MUX/DEMUX Chassis
  49. Canary Rackable/Standalone, Passive CWDM, (SC Client) Optical Add Drop Multiplexers [OADM]
  50. Canary Rackable/Standalone, Passive CWDM, (LC Client) Optical Add Drop Multiplexers [OADM]
  51. Active CWDM, Gigabit, UTP to Fiber, Standalone Converters
  52. Active CWDM, Gigabit Fiber to Fiber, Standalone Converters
  53. Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Standalone Converters
  54. Active CWDM, 100 Mb, UTP to Fiber, Standalone Converters
  55. Active CWDM, 100 Mb, Fiber to Fiber, Standalone Converters
  56. CCN-2000 Chassis, Passive CWDM, MUX/DEMUX Modules
  57. CCN-2000 / 0400 Chassis, Active CWDM, Gigabit UTP to Fiber, Converter Modules
  58. CCN-2000 / O400 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules
  59. CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules
  60. CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 2.125 Gigabaud, Fiber to Fiber, Converter Modules
  61. CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, UTP to Fiber, Converter Modules
  62. CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, Fiber to Fiber, Converter Modules
  63. CCM-1600 Chassis, Passive CWDM, MUX/DEMUX Modules
  64. CCM-1600 Chassis, Active CWDM, Gigabit, UTP to Fiber, Converter Modules
  65. CCM-1600 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules
  66. CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules
  67. CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 2.125 Gigabaud, Fiber to Fiber, Converter Modules
  68. CCM-1600 Chassis, Active CWDM, 100 Mb, UTP to Fiber, Converter Modules
  69. CCM-1600 Chassis, Active CWDM, 100 Mb, Fiber to Fiber, Converter Modules
 
List of Products by Family / Functional Groups
 
***Canary Gigabit Ethernet UTP to Fiber, Standalone Converters***
Model Number Standard Port / Function Description Port / Function Description
GFT-1055 1000BASE-T / SX Port 1: m/m, SC, 550m Port 2: RJ-45
       
GFT-1056 1000BASE-T / SX Port 1: m/m, LC, 550m Port 2: RJ-45
GFT-1055E 1000BASE-T / SX Port 1: m/m, SC, 2 Km Port 2: RJ-45
GFT-1031 1000BASE-T / LX Port 1: s/m, SC, 10Km Port 2: RJ-45
GFT-1031L 1000BASE-T / LX Port 1: s/m, SC, 30Km Port 2: RJ-45
GFT-1031XL 1000BASE-T / LX Port 1: s/m, SC, 40Km Port 2: RJ-45
GFT-1031E45 1000BASE-T / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: RJ-45
GFT-1031E75 1000BASE-T / LX Port 1: s/m, SC, 70Km Port 2: RJ-45
GFT-1036 1000BASE-T / LX Port 1: s/m, LC, 10Km Port 2: RJ-45
    Sgl. Fiber Bi-Directional  
GFT-1037A 1000BASE-T / LX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
GFT-1037B 1000BASE-T / LX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45
GFT-1037E4A 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
GFT-1037E4B 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45
[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.
GFT-10GBC 1000BASE-T / SX /LX Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: RJ-45
GFT-10SFP 1000BASE-T / SX /LX Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: RJ-45
  back to top
***Canary Gigabit Fiber to Fiber, Standalone Converters***
GFC-5555 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 550m
GFC-5555E 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 2Km
GFC-5353 1000BASE-SX / SX Port 1: m/m, MT-RJ, 550m Port 2: m/m, MT-RJ, 550m
       
GFC-5531 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 10Km
GFC-5333 1000BASE-SX / LX Port 1: m/m, MT-RJ, 550m Port 2: s/m, MT-RJ, 10Km
GFC-5531L 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 30Km
GFC-5531XL 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 40Km
GFC-5531E45 1000BASE-SX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 40Km
GFC-5531E75 1000BASE-SX / ZX Port 1: m/m, SC, 550m Port 2: s/m, SC, 70Km
GFC-3131 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 10Km
GFC-3333 1000BASE-LX / LX Port 1: s/m, MT-RJ, 10Km Port 2: s/m, MT-RJ, 10Km
GFC-3131L 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 30Km
GFC-3131E33 1000BASE-LX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 30Km
GFC-3131XL 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 40Km
GFC-3131E45 1000BASE-LX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 40Km
GFC-3131E75 1000BASE-LX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 70Km
GFC-3131E95 1000BASE-ZX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 100Km
    Sgl. Fiber Bi-Directional  
GFC-5537A 1000BASE-SX / LX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
GFC-5537B 1000BASE-SX / LX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
GFC-5537E4A 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
GFC-5537E4B 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

GFC-55GBC 1000BASE-LX / ZX Port 1: GBIC Slot, GBIC = SC, multiple lls and Transmit Distances Port 2: m/m, LC, 550m
GFC-55SFP 1000BASE-LX / ZX Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
  back to top
***Canary Fibre Channel, Fiber to Fiber, Standalone Converters***
  Fixed 1.0625 Gigabaud    
FC-155-55 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: m/m, SC, 550m
FC-155-31 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
FC-131-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 10Km Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
FC-156-56 ANSI X3T1 FC-AL Port 1: m/m, LC, 550m Fixed 1.0625 Gbd Port 2: m/m, LC, 550m
FC-156-36 ANSI X3T1 FC-AL Port 1: m/m, LC, 550m Fixed 1.0625 Gbd Port 2: s/m, LC, 10Km
FC-136-36 ANSI X3T1 FC-AL Port 1: s/m, LC, 10Km Fixed 1.0625 Gbd Port 2: s/m, LC, 10Km
    * Extended Reach Versions available e.g. FC-155-31E5 [50Km] or E8 [80Km]  
  Fixed 2.125 Gigabaud    
FC-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
FC-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
  back to top
***Canarynet 100 Fast Ethernet UTP to Fiber, Standalone Converters***
CFT-2061 100BASE-TX / FX Port 1: m/m, SC, 2Km Port 2: RJ-45
CFT-2062 100BASE-TX / FX Port 1: m/m, ST, 2Km Port 2: RJ-45
CFT-2063M 100BASE-TX / FX Port 1: m/m, MT-RJ, 2Km Port 2: RJ-45
CFT-2066 100BASE-TX / FX Port 1: m/m, LC, 2Km Port 2: RJ-45
       
CFT-2081-SM 100BASE-TX / FX Port 1: s/m, SC, 10Km Port 2: RJ-45
CFT-2061-SM 100BASE-TX / FX Port 1: s/m, SC, 20Km Port 2: RJ-45
CFT-2062-SM 100BASE-TX / FX Port 1: s/m, ST, 20Km Port 2: RJ-45
CFT-2063-SM 100BASE-TX / FX Port 1: s/m, MT-RJ, 20Km Port 2: RJ-45
CFT-2066-SM 100BASE-TX / FX Port 1: s/m, LC, 20Km Port 2: RJ-45
CFT-2061-LSM 100BASE-TX / FX Port 1: s/m, SC, 40Km Port 2: RJ-45
CFT-2061XL 100BASE-TX / FX Port 1: s/m, SC, 80Km Port 2: RJ-45
CFT-2061E85 100BASE-TX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: RJ-45
       
CFT-2067SA 100BASE-FX / TX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
CFT-2067SB 100BASE-FX / TX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45
CFT-2067E4A 100BASE-FX / TX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
CFT-2067E4B 100BASE-FX / TX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45
CFT-2067E6A 100BASE-FX / TX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
CFT-2067E6B 100BASE-FX / TX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top
***Canarynet 100 Fast Ethernet Fiber to Fiber, Standalone Converters***
CFC-2121 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, SC, 2Km
CFC-2122 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, ST, 2Km
CFC-2222 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, ST, 2Km
CFC-7221 10/100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, ST, 700m
CFC-7222 10/100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, ST, 700m
CFC-9121 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 20Km
CFC-9122 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 20Km
CFC-9172 100BASE-FX / FX Port 1: s/m, ST, 20Km Port 2: m/m, ST, 700m, 850hm
CFC-9191 100BASE-FX / FX Port 1: s/m, SC, 20Km Port 2: s/m, SC, 20Km
CFC-9221 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, ST, 20Km
CFC-9222 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, ST, 20Km
CFC-9272 100BASE-FX / FX Port 1: m/m, SC, 20Km Port 2: m/m, ST, 700m, 850hm
       
single F/O Bi-Directional s/m-m/m 20 Km
CFC-9721A 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CFC-9721B 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CFC-9722A 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CFC-9722B 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CFC-9721E4A 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CFC-9721E4B 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CFC-9721E6A 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CFC-9721E6B 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CFC-9722E4A 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CFC-9722E4B 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CFC-9722E6A 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CFC-9722E6B 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
single F/O Bi-Directional s/m-s/m 20 Km
CFC-9791A 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, SC, 20Km
CFC-9791B 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, SC, 20Km
CFC-9792A 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, ST, 20Km
CFC-9792B 100BASE-FX / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, ST, 20Km
CFC-9791E4A 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, SC, 20Km
CFC-9791E4B 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, SC, 20Km
CFC-9792E4A 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, ST, 20Km
CFC-9792E4B 100BASE-FX / FX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, ST, 20Km
CFC-9791E6A 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, SC, 20Km
CFC-9791E6B 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, SC, 20Km
CFC-9792E6A 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: s/m, ST, 20Km
CFC-9792E6B 100BASE-FX / FX Port 1: s/m, SC, 60Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: s/m, ST, 20Km

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

       
CFC-9121L 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 40Km
CFC-9122L 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 40Km
CFC-9121XL 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 80Km
CFC-9121E85 100BASE-FX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 80Km
CFC-9122XL 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 80Km
CFC-9122E85 100BASE-FX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 80Km
CFC-9191L 100BASE-FX / FX Port 1: s/m, SC, 20Km Port 2: s/m, SC, 40Km
CFC-9192L 100BASE-FX / FX Port 1: s/m, ST, 20Km Port 2: s/m, SC, 40Km
  back to top
***10Mbs Standalone Mini-Converters***
MCC-2000 10BASE-2 / 10BASE-T Port 1: BNC Port 2: RJ-45
MCC-2012 10BASE-2 / 10BASE-FL Port 1: BNC Port 2: (ST) m/m, 2Km
MCC-2012-SM 10BASE-2 / 10BASE-FL Port 1: BNC Port 2: (ST) s/m, 4Km
MCC-2022 10BASE-T / 10BASE-FL Port 1: RJ-45 Port 2: (ST) m/m, 2Km
MCC-2022-SC 10BASE-T / 10BASE-FL Port 1: RJ-45 Port 2: (SC) m/m, 2Km
MCC-2022-SM 10BASE-T / 10BASE-FL Port 1: RJ-45 Port 2: (ST) s/m, 15Km
CSH-0001 19" 5 Half Shelf for MCC Converters    
  back to top
***2 Port LAN Extenders*** Standalone, (Two-Port 10/100 Bridges)
CLE-1000 10/100BASE-T / TX 2 Ports: RJ-45 512K Buffer
CLE-1061 10/100BASE-T / FX Port 1: m/m, SC, 2Km Port 2: RJ-45 512K Buffer
       
       
CLE-1062 10/100BASE-T / FX Port 1: m/m, ST, 2Km Port 2: RJ-45 512K Buffer
CLE-1061S 10/100BASE-T / FX Port 1: s/m, SC, 20Km Port 2: RJ-45 512K Buffer
CLE-1062S 10/100BASE-T / FX Port 1: s/m, ST, 20Km Port 2: RJ-45 512K Buffer
CLE-1061E43 10/100BASE-T / FX Port 1: s/m, SC, 40Km Port 2: RJ-45 512K Buffer
CLE-1067SA 10/100BASE-T / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45 512K Buffer
CLE-1067SB 10/100BASE-T / FX Port 1: s/m, SC, 20Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45 512K Buffer
[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.
  back to top
***Basic Connections! series of Economical "no frills", Standalone Media Conversion***
BC-TFM1 100BASE-TX / FX Port 1: m/m, SC, 2Km Port 2: RJ-45
BC-TFM2 100BASE-TX / FX Port 1: m/m, ST, 2Km Port 2: RJ-45
BC-TFS1 100BASE-TX / FX Port 1: s/m, SC, 20Km Port 2: RJ-45
BC-TFS2 100BASE-TX / FX Port 1: s/m, ST, 20Km Port 2: RJ-45
BC-TFS1-L4 100BASE-TX / FX Port 1: s/m, SC, 40Km Port 2: RJ-45
BC-GTSX1 1000BASE-T / SX Port 1: m/m, SC, 550m Port 2: RJ-45
BC-GTLX1 1000BASE-T / LX Port 1: s/m, SC, 10Km Port 2: RJ-45
BC-GSXLX1 1000BASE-SX / LX Port 1: s/m, SC, 10Km Port 2: m/m, SC, 550m
  back to top
***Serial RS to Fiber Optic, Standalone Converters**
CSC-2D9-M1 RS-232 - m/m Fiber Port 1: DB-9 Port 2: m/m, SC, 2Km
CSC-2D9-M2 RS-232 - m/m Fiber Port 1: DB-9 Port 2: m/m, ST, 2Km
CSC-2D9-S1 RS-232 - s/m Fiber Port 1: DB-9 Port 2: s/m, SC, 20Km
CSC-2D9-S2 RS-232 - s/m Fiber Port 1: DB-9 Port 2: s/m, ST, 20Km
CSC-2D9-S1E4 RS-232 - s/m Fiber Port 1: DB-9 Port 2: s/m, SC, 40Km
CSC-4D9-M1 RS-422 / 485-m/m Fiber Port 1: DB-9 Port 2: m/m, SC, 2Km
CSC-4D9-M2 RS-422 / 485-m/m Fiber Port 1: DB-9 Port 2: m/m, ST, 2Km
CSC-4D9-S1 RS-422 / 485-s/m Fiber Port 1: DB-9 Port 2: s/m, SC, 20Km
CSC-4D9-S2 RS-422 / 485-s/m Fiber Port 1: DB-9 Port 2: s/m, ST, 20Km
CSC-4D9-S1E4 RS-422 / 485-s/m Fiber Port 1: DB-9 Port 2: s/m, SC, 40Km
  back to top
***Serial RS to Fast Ethernet UTP / Fiber Optic, Standalone Converters**
CSE-D9TX RS-232/422/485 to 100B-TX Port 1: DB-9 Port 2: RJ-45, 100m
CSE-D9M1 RS-232/422/485 to 100B-FX Port 1: DB-9 Port 2: m/m, SC, 2Km
CSE-D9M2 RS-232/422/485 to 100B-FX Port 1: DB-9 Port 2: m/m, ST, 2Km
CSE-D9S1 RS-232/422/485 to 100B-FX Port 1: DB-9 Port 2: s/m, SC, 20Km
CSE-D9S2 RS-232/422/485 to 100B-FX Port 1: DB-9 Port 2: s/m, ST, 20Km
CSE-D9E4 RS-232/422/485 to 100B-FX Port 1: DB-9 Port 2: s/m, SC, 40Km
  back to top
***Canary ConversionNet 2000 Rack Mount Modular Converters***
CCN-0400   4-Port Chassis 100 / 230 Volt AC Internal Power Supply  
CCN-2000   20-Port Chassis 100 / 230 Volt AC Internal PWR Supply  
CN-200048V   20-Port Chassis -48 Volt DC Internal Power Supply  
CN-20MGNT   Management Card: [2] RJ-45, 10 pin [serial ports], [1] 100BASE-T LAN port  
CN-20RP   Redundant 100 / 230 Volt AC Power Supply Module With Diagnostics  
CN-20RP48V   Redundant -48 Volt DC Power Supply Module With Diagnostics  
CN-20RFAN   Redundant Fan Assembly With Diagnostics  
CN-CD9RJ10P   Cable assembly DB9 to RJ-45 type (10-pin)  
  back to top
***CCN-2000 / 0400 Chassis, 100Mb UTP to Fiber Converter Modules**
CN-2041 100BASE-FX / TX Port 1: m/m, SC, 2Km Port 2: RJ-45
CN-2042 100BASE-FX / TX Port 1: m/m, ST, 2Km Port 2: RJ-45
       
CN-2081S 100BASE-FX / TX Port 1: s/m, SC, 10Km Port 2: RJ-45
CN-2041S 100BASE-FX / TX Port 1: s/m, SC, 20Km Port 2: RJ-45
CN-2042S 100BASE-FX / TX Port 1: s/m, ST, 20Km Port 2: RJ-45
CN-2041E43 100BASE-FX / TX Port 1: s/m, SC, 40Km Port 2: RJ-45
CN-2041E85 100BASE-FX / TX Port 1: s/m, SC, 80Km Port 2: RJ-45
       
CN-2047SA 100BASE-FX / TX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CN-2047SB 100BASE-FX / TX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CN-2047E4A 100BASE-FX / TX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CN-2047E4B 100BASE-FX / TX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CN-2047E6A 100BASE-FX / TX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CN-2047E6B 100BASE-FX / TX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top
***CCN-2000 / 0400 Chassis, 100 Mb Fiber to Fiber Converter Modules***
CN-B113 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, SC, 2Km
CN-B123 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, SC, 2Km
CN-B223 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, ST, 2Km
CN-B9191 100BASE-FX / FX Port 1: s/m, SC, 20Km Port 2: s/m, SC, 20Km
CN-C113 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 20Km
CN-C123 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 20Km
CN-C213 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, ST, 20Km
CN-C223 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, ST, 20Km
CN-C113E4 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 40Km
CN-C123E4 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 40Km
CN-C115E8 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 80Km
CN-C125E8 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 80Km
    Sgl. Fiber Bi-Directional  
CN-C17SA 100BASE-FX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CN-C17SB 100BASE-FX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CN-C27SA 100BASE-FX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CN-C27SB 100BASE-FX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CN-C17E4A 100BASE-FX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CN-C17E4B 100BASE-FX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CN-C17E6A 100BASE-FX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CN-C17E6B 100BASE-FX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CN-C27E4A 100BASE-FX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CN-C27E4B 100BASE-FX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CN-C27E6A 100BASE-FX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CN-C27E6B 100BASE-FX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top
***CCN-2000 / 0400 Chassis, Gigabit UTP to Fiber Converter Modules***
CN-1055 1000BASE-T / SX Port 1: m/m, SC, 550m Port 2: RJ-45
CN-1055E 1000BASE-T / SX Port 1: m/m, SC, 2Km Port 2: RJ-45
CN-1031 1000BASE-T / LX Port 1: s/m, SC, 10Km Port 2: RJ-45
CN-1031E33 1000BASE-T / LX Port 1: s/m, SC, 30Km Port 2: RJ-45
CN-1031E45 1000BASE-T / LX Port 1: s/m, SC, 40Km Port 2: RJ-45
CN-1031E75 1000BASE-T / LX Port 1: s/m, SC, 70Km Port 2: RJ-45
    Sgl. Fiber Bi-Directional  
CN-1037A 1000BASE-T / LX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CN-1037B 1000BASE-T / LX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CN-1037E4A 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
CN-1037E4B 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

CN-10GBC 1000BASE-T / SX /LX Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: RJ-45
CN-10SFP 1000BASE-T / SX /LX Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: RJ-45
  back to top
***CCN-2000 / 0400 Chassis, Gigabit Fiber to Fiber Converter Modules***
CN-5555 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 550m
CN-5555E 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 2Km
CN-5353 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 550m
CN-5531 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 10Km
CN-5531E33 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 30Km
CN-5531E45 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 40Km
CN-5531E75 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 70Km
CN-3131 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 10Km
CN-3131E33 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 30Km
CN-3131E75 1000BASE-LX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 70Km
CN-3131E95 1000BASE-ZX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 100Km
    Sgl. Fiber Bi-Directional  
CN-5537A 1000BASE-SX / LX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 550m
CN-5537B 1000BASE-SX / LX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 550m
CN-5537E4A 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 550m
CN-5537E4B 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 550m

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top
***CCN-2000 / 0400 Chassis, Fibre Channel, Fiber to Fiber Converter Modules***
  Fixed 1.0625 Gigabaud    
CN-155-55 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: m/m, SC, 550m
CN-155-31 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
CN-131-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 10Km Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
CN-156-56 ANSI X3T1 FC-AL Port 1: m/m, LC, 550m Fixed 1.0625 Gbd Port 2: m/m, LC, 550m
CN-156-36 ANSI X3T1 FC-AL Port 1: m/m, LC, 550m Fixed 1.0625 Gbd Port 2: s/m, LC, 10Km
CN-136-36 ANSI X3T1 FC-AL Port 1: s/m, LC, 10Km Fixed 1.0625 Gbd Port 2: s/m, LC, 10Km
    * Extended Reach Versions available e.g. CN-155-31E5 [50Km] or E8 [80Km]  
  Fixed 2.125 Gigabaud    
CN-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CN-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
  back to top
***CCN-2000 Chassis, Passive CWDM, MUX/DEMUX Modules**
CN-4MD6-A [4] Mux/Demx, s/m LC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CN-4MD6-B [4] Mux/Demx, s/m LC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CN-4MD6-C [4] Mux/Demx, s/m LC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CN-4MD6-D [4] Mux/Demx, s/m LC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CN-4MD6-M [4] Mux/Demx, s/m LC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CN-8MD6-E [8] Mux/Demx, s/m LC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, C,
CN-8MD6-F [8] Mux/Demx, s/m LC Group-C+D ls: 1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-8MD6-M [8] Mux/Demx, s/m LC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-12MD6-G [12] Mux/Demx, s/m LC Group-E ls, Plus C ls : 1290, 1310, 1330, 1350 hm NW Port: s/m, SC,
CN-12MD6-H [12] Mux/Demx, s/m LC Group-E ls, Plus D ls : 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-12MD6-M [12] Mux/Demx, s/m LC Group-E ls, Plus C ls: 1310, 1330, 1350, + 1370 hm (Group-D) NW Port: s/m, SC,
  back to top
***CCN-2000 / 0400 Chassis, Active CWDM, Gigabit UTP to Fiber, Converter Modules**
CN-10W-27 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: RJ-45
CN-10W-29 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: RJ-45
CN-10W-31 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: RJ-45
CN-10W-33 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: RJ-45
CN-10W-35 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: RJ-45
CN-10W-37 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: RJ-45
CN-10W-39 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: RJ-45
CN-10W-41 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: RJ-45
CN-10W-43 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: RJ-45
CN-10W-45 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: RJ-45
CN-10W-47 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: RJ-45
CN-10W-49 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: RJ-45
CN-10W-51 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: RJ-45
CN-10W-53 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: RJ-45
CN-10W-55 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: RJ-45
CN-10W-57 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: RJ-45
CN-10W-59 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: RJ-45
CN-10W-61 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CN-10W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules**

CN-55W-27 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m SC, 550m
CN-55W-29 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m SC, 550m
CN-55W-31 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m SC, 550m
CN-55W-33 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m SC, 550m
CN-55W-35 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m SC, 550m
CN-55W-37 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m SC, 550m
CN-55W-39 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m SC, 550m
CN-55W-41 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m SC, 550m
CN-55W-43 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m SC, 550m
CN-55W-45 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m SC, 550m
CN-55W-47 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m SC, 550m
CN-55W-49 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m SC, 550m
CN-55W-51 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m SC, 550m
CN-55W-53 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m SC, 550m
       
CN-55W-55 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m SC, 550m
CN-55W-57 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m SC, 550m
CN-55W-59 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m SC, 550m
CN-55W-61 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m SC, 550m
    * Extended Reach Versions available e.g. CN-55W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 1.0625 Gigabaud    
CN-155W-27 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m, SC, 550m
CN-155W-29 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m, SC, 550m
CN-155W-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m, SC, 550m
CN-155W-33 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m, SC, 550m
CN-155W-35 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m, SC, 550m
CN-155W-37 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m, SC, 550m
CN-155W-39 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m, SC, 550m
CN-155W-41 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m, SC, 550m
CN-155W-43 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m, SC, 550m
CN-155W-45 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m, SC, 550m
CN-155W-47 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m, SC, 550m
CN-155W-49 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m, SC, 550m
CN-155W-51 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m, SC, 550m
CN-155W-53 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m, SC, 550m
CN-155W-55 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m, SC, 550m
CN-155W-57 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m, SC, 550m
CN-155W-59 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m, SC, 550m
CN-155W-61 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m, SC, 550m
    * Extended Reach Versions available e.g. CN-155W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 2.125Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 2.125 Gigabaud    
CN-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CN-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, UTP to Fiber, Converter Modules**

CN-20W-27 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: RJ-45
CN-20W-29 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: RJ-45
CN-20W-31 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: RJ-45
CN-20W-33 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: RJ-45
CN-20W-35 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: RJ-45
CN-20W-37 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: RJ-45
CN-20W-39 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: RJ-45
CN-20W-41 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: RJ-45
CN-20W-43 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: RJ-45
CN-20W-45 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: RJ-45
CN-20W-47 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: RJ-45
CN-20W-49 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: RJ-45
CN-20W-51 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: RJ-45
CN-20W-53 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: RJ-45
CN-20W-55 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: RJ-45
       
CN-20W-57 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: RJ-45
CN-20W-59 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: RJ-45
CN-20W-61 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CN-20W-27E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, Fiber to Fiber, Converter Modules**

CN-C11W-27 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: m/m, SC, 2Km
CN-C11W-29 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: m/m, SC, 2Km
CN-C11W-31 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: m/m, SC, 2Km
CN-C11W-33 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: m/m, SC, 2Km
CN-C11W-35 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: m/m, SC, 2Km
CN-C11W-37 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: m/m, SC, 2Km
CN-C11W-39 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: m/m, SC, 2Km
CN-C11W-41 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: m/m, SC, 2Km
CN-C11W-43 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: m/m, SC, 2Km
CN-C11W-45 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: m/m, SC, 2Km
CN-C11W-47 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: m/m, SC, 2Km
CN-C11W-49 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: m/m, SC, 2Km
CN-C11W-51 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: m/m, SC, 2Km
CN-C11W-53 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: m/m, SC, 2Km
CN-C11W-55 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: m/m, SC, 2Km
CN-C11W-57 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: m/m, SC, 2Km
CN-C11W-59 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: m/m, SC, 2Km
CN-C11W-61 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: m/m, SC, 2Km
    * Extended Reach Versions available e.g. CN-C11W-27E8 [80Km]  
  back to top

***Canarynet 100 CCM-1600 Rack Mount Modular Converter Chassis***

CCM-1600   16-Port Chassis 100 / 230 Volt AC Internal PWR Supply  
CCM-1600-48V   16-Port Chassis -48 Volt DC Internal Power Supply  
CCM-12RPS   Redundant 100 / 230 Volt AC Power Supply Module  
CCM-12RPS48V   Redundant -48 Volt DC Power Supply Module  
  back to top

***CCM-1600 Chassis 10 Mb Converter Modules***

CCM-1201 10BASE-2 / FL Port 1: BNC Port 2: (ST) m/m, 2Km
CCM-1201-SM 10BASE-2 / FL Port 1: BNC Port 2: (ST) s/m, 4Km
CCM-1202 10BASE-T / FL Port 1: RJ-45 Port 2: (ST) m/m, 2Km
CCM-1202-SC 10BASE-T / FL Port 1: RJ-45 Port 2: (SC) m/m, 2Km
CCM-1202-SM 10BASE-T / FL Port 1: RJ-45 Port 2: (ST) s/m, 15Km
CCM-1203 10BASE-2 / T Port 1: BNC Port 2: RJ-45
  back to top

***CCM-1600 Chassis 100 Mb UTP to Fiber Converter Modules***

CCM-1241 100BASE-TX / FX Port 1: (SC) m/m, 2Km Port 2: RJ-45
CCM-1242 100BASE-TX / FX Port 1: (ST) m/m, 2Km Port 2: RJ-45
CCM-1243M 100BASE-TX / FX Port 1: (MT-RJ) m/m, 2Km Port 2: RJ-45
CCM-1281-SM 100BASE-TX / FX Port 1: (SC) s/m, 10Km Port 2: RJ-45
CCM-1241-SM 100BASE-TX / FX Port 1: (SC) s/m, 20Km Port 2: RJ-45
CCM-1242-SM 100BASE-TX / FX Port 1: (ST) s/m, 20Km Port 2: RJ-45
CCM-1243-SM 100BASE-TX / FX Port 1: (MT-RJ) s/m, 20Km Port 2: RJ-45
CCM-1241-LSM 100BASE-TX / FX Port 1: (SC) s/m, 40Km Port 2: RJ-45
       
CCM-1241XL 100BASE-TX / FX Port 1: (SC) s/m, 80Km Port 2: RJ-45
CCM-1241E85 100BASE-TX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: RJ-45
    Sgl. Fiber Bi-Directional  
CCM-1247SA 100BASE-TX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CCM-1247SB 100BASE-TX / FX Port 1: (SC) s/m, 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CCM-1247E4A 100BASE-TX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CCM-1247E4B 100BASE-TX / FX Port 1: (SC) s/m, 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CCM-1247E6A 100BASE-TX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CCM-1247E6B 100BASE-TX / FX Port 1: (SC) s/m, 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top

***CCM-1600 Chassis 10/100 Mbs Fiber to Fiber Converter Modules***

CCM-2121 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, SC, 2Km
CCM-2122 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, SC, 2Km
CCM-2222 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, ST, 2Km
CCM-7221 10/100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: m/m, ST, 700m, 850hm
CCM-7222 10/100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: m/m, ST, 700m, 850hm
CCM-9121 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 20Km
CCM-9122 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 20Km
CCM-9172 100BASE-FX / FX Port 1: s/m, SC, 20Km Port 2: m/m, ST, 700m, 850hm
CCM-9221 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, ST, 20Km
CCM-9222 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, ST, 20Km
CCM-9272 100BASE-FX / FX Port 1: m/m, ST, 20Km Port 2: m/m, ST, 700m, 850hm
CCM-9191 100BASE-FX / FX Port 1: s/m, SC, 20Km Port 2: s/m, SC, 20Km
CCM-9121L 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 40Km
CCM-9122L 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 40Km
CCM-9121XL 100BASE-FX / FX Port 1: m/m, SC, 2Km Port 2: s/m, SC, 80Km
CCM-9121E85 100BASE-FX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 80Km
CCM-9122XL 100BASE-FX / FX Port 1: m/m, ST, 2Km Port 2: s/m, SC, 80Km
CCM-9122E85 100BASE-FX / FX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 80Km
    Sgl. Fiber Bi-Directional  
CCM-9721A 100BASE-FX / FX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CCM-9721B 100BASE-FX / FX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CCM-9722A 100BASE-FX / FX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CCM-9722B 100BASE-FX / FX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CCM-9721E4A 100BASE-FX / FX Port 1: s/m, SC 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CCM-9721E4B 100BASE-FX / FX Port 1: s/m, SC 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CCM-9721E6A 100BASE-FX / FX Port 1: s/m, SC 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 2Km
CCM-9721E6B 100BASE-FX / FX Port 1: s/m, SC 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 2Km
CCM-9722E4A 100BASE-FX / FX Port 1: s/m, SC 40Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CCM-9722E4B 100BASE-FX / FX Port 1: s/m, SC 40Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km
CCM-9722E6A 100BASE-FX / FX Port 1: s/m, SC 60Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, ST, 2Km
CCM-9722E6B 100BASE-FX / FX Port 1: s/m, SC 60Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, ST, 2Km

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top
***CCM-1600 Chassis Gigabit UTP to Fiber Converter Modules***
CCM-1055 1000BASE-T / SX Port 1: m/m, SC, 550m Port 2: RJ-45
CCM-1053 1000BASE-T / SX Port 1: m/m, MT-RJ, 550m Port 2: RJ-45
CCM-1055E 1000BASE-T / SX Port 1: m/m, SC, 2Km Port 2: RJ-45
       
CCM-1031 1000BASE-T / LX Port 1: s/m, SC, 10Km Port 2: RJ-45
CCM-1031L 1000BASE-T / LX Port 1: s/m, SC, 30Km Port 2: RJ-45
CCM-1031XL 1000BASE-T / LX Port 1: s/m, SC, 40Km Port 2: RJ-45
CCM-1031E45 1000BASE-T / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: RJ-45
CCM-1031XL75 1000BASE-T / LX Port 1: s/m, SC, 70Km Port 2: RJ-45
CCM-1031E75 1000BASE-T / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: RJ-45
CCM-1033 1000BASE-T / LX Port 1: s/m, MT-RJ, 10Km Port 2: RJ-45
    Sgl. Fiber Bi-Directional  
CCM-1037A 1000BASE-T / LX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: RJ-45
CCM-1037B 1000BASE-T / LX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: RJ-45
CCM-1037E4A 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: RJ-45
CCM-1037E4B 1000BASE-T / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: RJ-45

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

CCM-10GBC 1000BASE-T / SX /LX Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: RJ-45
CCM-10SFP 1000BASE-T / SX /LX Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: RJ-45
  back to top
***CCM-1600 Chassis Gigabit Fiber to Fiber Converter Modules***
CCM-5555 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 550m
CCM-5555E 1000BASE-SX / SX Port 1: m/m, SC, 550m Port 2: m/m, SC, 2Km
CCM-5353 1000BASE-SX / SX Port 1: m/m, MT-RJ, 550m Port 2: m/m, MT-RJ, 550m
CCM-5531 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 10Km
CCM-5333 1000BASE-SX / LX Port 1: m/m, MT-RJ, 550m Port 2: s/m, MT-RJ, 10Km
CCM-5531L 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 30Km
CCM-5531XL 1000BASE-SX / LX Port 1: m/m, SC, 550m Port 2: s/m, SC, 40Km
CCM-5531E45 1000BASE-SX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 40Km
CCM-5531XL75 1000BASE-SX / ZX Port 1: m/m, SC, 550m Port 2: s/m, SC, 70Km
CCM-5531E75 1000BASE-SX / ZX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 70Km
CCM-3131 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 10Km
CCM-3333 1000BASE-LX / LX Port 1: s/m, MT-RJ, 10Km Port 2: s/m, MT-RJ, 10Km
CCM-3131L 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 30Km
CCM-3131E33 1000BASE-LX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 30Km
CCM-3131XL 1000BASE-LX / LX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 40Km
CCM-3131E45 1000BASE-LX / LX SAME AS ABOVE - ALTERNATE MODEL NUMBER Port 2: s/m, SC, 40Km
CCM-3131E75 1000BASE-LX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 70Km
CCM-3131E95 1000BASE-ZX / ZX Port 1: s/m, SC, 10Km Port 2: s/m, SC, 100Km
    Sgl. Fiber Bi-Directional  
CCM-5537A 1000BASE-SX / LX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1550 Rx 1310 Port 2: m/m, SC, 550m
CCM-5537B 1000BASE-SX / LX Port 1: s/m, SC 20Km Sgl. Fiber Bi-Direct:Tx 1310 Rx 1550 Port 2: m/m, SC, 550m
CCM-5537E4A 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1550 Rx 1310 Port 2: m/m, SC, 550m
CCM-5537E4B 1000BASE-SX / LX Port 1: s/m, SC, 40Km Sgl. Fiber Bi-Direct: Tx 1310 Rx 1550 Port 2: m/m, SC, 550m

[A] VERSIONS OF STANDALONE OR CHASSIS MODULE MUST BE PAIRED WITH A. [B] VERSION TO FUNCTION PROPERLY.

  back to top

***CCM-1600 Chassis, Fibre Channel, Fiber to Fiber Converter Modules***

  Fixed 1.0625 Gigabaud    
CM-155-55 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: m/m, SC, 550m
CM-155-31 ANSI X3T1 FC-AL Port 1: m/m, SC, 550m Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
CM-131-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 10Km Fixed 1.0625 Gbd Port 2: s/m, SC, 10Km
2 Gigabit Fixed Fixed 2.125 Gigabaud    
CM-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CM-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: s/m, LC, 550m
  back to top

***CCM-1600 Chassis, Passive CWDM, MUX/DEMUX Modules**

CM-4MD6-A [4] Mux/Demx, s/m LC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CM-4MD6-B [4] Mux/Demx, s/m LC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CM-4MD6-C [4] Mux/Demx, s/m LC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CM-4MD6-D [4] Mux/Demx, s/m LC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CM-4MD6-M [4] Mux/Demx, s/m LC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CM-8MD6-E [8] Mux/Demx, s/m LC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, SC,
CM-8MD6-F [8] Mux/Demx, s/m LC Group-C+D ls: 1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CM-8MD6-M [8] Mux/Demx, s/m LC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
  back to top

***CCM-1600 Chassis, Active CWDM, Gigabit, UTP to Fiber, Converter Modules**

CM-10W-27 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: RJ-45
CM-10W-29 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: RJ-45
CM-10W-31 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: RJ-45
CM-10W-33 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: RJ-45
CM-10W-35 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: RJ-45
CM-10W-37 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: RJ-45
CM-10W-39 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: RJ-45
CM-10W-41 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: RJ-45
CM-10W-43 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: RJ-45
CM-10W-45 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: RJ-45
CM-10W-47 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: RJ-45
CM-10W-49 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: RJ-45
CM-10W-51 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: RJ-45
CM-10W-53 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: RJ-45
CM-10W-55 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: RJ-45
CM-10W-57 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: RJ-45
CM-10W-59 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: RJ-45
CM-10W-61 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CM-10W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules**

CM-55W-27 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m SC, 550m
CM-55W-29 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m SC, 550m
CM-55W-31 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m SC, 550m
CM-55W-33 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m SC, 550m
CM-55W-35 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m SC, 550m
CM-55W-37 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m SC, 550m
CM-55W-39 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m SC, 550m
CM-55W-41 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m SC, 550m
CM-55W-43 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m SC, 550m
CM-55W-45 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m SC, 550m
CM-55W-47 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m SC, 550m
CM-55W-49 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m SC, 550m
CM-55W-51 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m SC, 550m
CM-55W-53 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m SC, 550m
CM-55W-55 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m SC, 550m
CM-55W-57 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m SC, 550m
CM-55W-59 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m SC, 550m
CM-55W-61 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m SC, 550m
    * Extended Reach Versions available e.g. CM-55W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 1.0625 Gigabaud    
CM-155W-27 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m, SC, 550m
CM-155W-29 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m, SC, 550m
CM-155W-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m, SC, 550m
CM-155W-33 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m, SC, 550m
CM-155W-35 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m, SC, 550m
CM-155W-37 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m, SC, 550m
CM-155W-39 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m, SC, 550m
CM-155W-41 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m, SC, 550m
CM-155W-43 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m, SC, 550m
CM-155W-45 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m, SC, 550m
CM-155W-47 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m, SC, 550m
CM-155W-49 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m, SC, 550m
CM-155W-51 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m, SC, 550m
CM-155W-53 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m, SC, 550m
CM-155W-55 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m, SC, 550m
CM-155W-57 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m, SC, 550m
CM-155W-59 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m, SC, 550m
CM-155W-61 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m, SC, 550m
    * Extended Reach Versions available e.g. CM-155W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 2.125Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 2.125 Gigabaud    
CM-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CM-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: s/m, LC, 550m
  back to top

***CCM-1600 Chassis, Active CWDM, 100 Mb, UTP to Fiber, Converter Modules**

CM-12W-27 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: RJ-45
CM-12W-29 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: RJ-45
CM-12W-31 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: RJ-45
CM-12W-33 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: RJ-45
CM-12W-35 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: RJ-45
CM-12W-37 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: RJ-45
CM-12W-39 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: RJ-45
CM-12W-41 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: RJ-45
CM-12W-43 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: RJ-45
CM-12W-45 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: RJ-45
CM-12W-47 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: RJ-45
CM-12W-49 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: RJ-45
CM-12W-51 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: RJ-45
CM-12W-53 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: RJ-45
CM-12W-55 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: RJ-45
CM-12W-57 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: RJ-45
CM-12W-59 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: RJ-45
CM-12W-61 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CM-12W-27E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, 100 Mb, Fiber to Fiber, Converter Modules**

CM-91W-27 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: m/m, SC, 2Km
CM-91W-29 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: m/m, SC, 2Km
CM-91W-31 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: m/m, SC, 2Km
CM-91W-33 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: m/m, SC, 2Km
CM-91W-35 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: m/m, SC, 2Km
CM-91W-37 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: m/m, SC, 2Km
CM-91W-39 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: m/m, SC, 2Km
CM-91W-41 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: m/m, SC, 2Km
CM-91W-43 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: m/m, SC, 2Km
CM-91W-45 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: m/m, SC, 2Km
CM-91W-47 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: m/m, SC, 2Km
CM-91W-49 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: m/m, SC, 2Km
CM-91W-51 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: m/m, SC, 2Km
CM-91W-53 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: m/m, SC, 2Km
CM-91W-55 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: m/m, SC, 2Km
CM-91W-57 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: m/m, SC, 2Km
CM-91W-59 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: m/m, SC, 2Km
CM-91W-61 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: m/m, SC, 2Km
    * Extended Reach Versions available e.g. CM-91W-27E8 [80Km]  
  back to top

***Unmanaged 10/100 UTP, Fixed Configuration, Switches***

CWX-5T 10/100BASE-T / TX [Five] RJ-45 Ports Mini Switch  
CWX-8T 10/100BASE-T / TX [Eight] RJ-45 Ports Desktop Switch  
CWX-16T 10/100BASE-T / TX [Sixteen] RJ-45 Ports Workgroup Switch  
CWX-24T 10/100BASE-T / TX [Twenty-Four] RJ-45 Ports Workgroup Switch  
  back to top

***Managed 10/100 UTP / Fiber Optic, Media Converters***

Two Ports      
CMX-1011 10/100BASE-TX / FX [One] RJ-45 Port [One] m/m SC, 2Km Port
CMX-1012 10/100BASE-TX / FX [One] RJ-45 Port [One] m/m ST, 2Km Port
CMX-1011S 10/100BASE-TX / FX [One] RJ-45 Port [One] s/m SC, 20Km Port
CMX-1012S 10/100BASE-TX / FX [One] RJ-45 Port [One] s/m ST, 20Km Port
Redundant Ports Two Active + Two Spares    
CMX-1011R 10/100BASE-TX / FX [Two] RJ-45 Ports: Primary + Redundant RJ-45 and Fiber Ports [Two] m/m SC, 2Km Ports
CMX-1012R 10/100BASE-TX / FX [Two] RJ-45 Ports Primary + Redundant RJ-45 and Fiber Ports [Two] m/m ST, 2Km Ports
CMX-1011RS 10/100BASE-TX / FX [Two] RJ-45 Ports Primary + Redundant RJ-45 and Fiber Ports [Two] s/m SC, 20Km Ports
CMX-1012RS 10/100BASE-TX / FX [Two] RJ-45 Ports Primary + Redundant RJ-45 and Fiber Ports [Two] s/m ST, 20Km Ports
  back to top

***Managed 10/100 UTP / Fiber Optic, Fixed-Configuration, Multi-Media Switches***

Five Ports      
CMX-4011 10/100BASE-TX / FX [Four] RJ-45 Ports [One] m/m SC, 2Km Port
CMX-4012 10/100BASE-TX / FX [Four] RJ-45 Ports [One] m/m ST, 2Km Port
CMX-4011S 10/100BASE-TX / FX [Four] RJ-45 Ports [One] s/m SC, 20Km Port
CMX-4012S 10/100BASE-TX / FX [Four] RJ-45 Ports [One] s/m ST, 20Km Port
Six Ports      
CMX-4021 10/100BASE-TX / FX [Four] RJ-45 Ports [Two] m/m SC, 2Km Ports
CMX-4022 10/100BASE-TX / FX [Four] RJ-45 Ports [Two] m/m ST, 2Km Ports
CMX-4021S 10/100BASE-TX / FX [Four] RJ-45 Ports [Two] s/m SC, 20Km Ports
CMX-4022S 10/100BASE-TX / FX [Four] RJ-45 Ports [Two] s/m ST, 20Km Ports
  back to top

***Managed or Smart [Configurable / Modular] 24-Port, 10/100 UTP / Fiber Optic + Gigabit, Multi-Media Switches***

CMX-2400G 10/100/1000BASE-T/TX / FX Up to [24] Ports, in 8-Port groups, of RJ-45 or LC Fiber Modules [Two] optional GBIC Ports
CSX-2400G 10/100/1000BASE-T/TX / FX Up to [24] Ports, in 8-Port groups, of RJ-45 or LC Fiber Modules [Two] optional GBIC Ports
CMX-8TX 10/100BASE-TX [Eight] RJ-45 Ports UTP Module  
CMX-8M6 100BASE-FX [Eight] m/m LC Ports Fiber Module  
CMX-8S6 100BASE-FX [Eight] s/m LC Ports Fiber Module  
CMX-4M1 100BASE-FX [Four] m/m SC Ports Fiber Module  
CMX-4M2 100BASE-FX [Four] m/m ST Ports Fiber Module  
CMX-4S1 100BASE-FX [Four] s/m SC Ports Fiber Module  
CMX-4S2 100BASE-FX [Four] s/m ST Ports Fiber Module  
CGB-55SX 1000BASE-SX [One] m/m SC Port Fiber GBIC SX, 550m  
CGB-31LX 1000BASE-LX [One] s/m SC Port Fiber GBIC LX, 10Km  
CGB-1000T 1000BASE-T [One] RJ-45 Port UTP Module  
  back to top

***WAVEPLEX 2000 2-Channel Wavelength Division Multiplexers {100 Mb Media Converters}***

CWM-2001 100BASE-TX / FX Client Side input / output: UTP / UTP WDM Fiber Link Port: m/m
CWM-2001-SM 100BASE-TX / FX Client Side input / output: UTP / UTP WDM Fiber Link Port: s/m
CWM-2011-P 100BASE-TX / FX Client Side input / output: UTP, one Passive [pass-thru] F/O m/m WDM Fiber Link Port: m/m
CWM-2011-PSM 100BASE-TX / FX Client Side input / output: UTP, one Passive [pass-thru] F/O s/m WDM Fiber Link Port: s/m
CWM-2011-SM 100BASE-TX / FX Client Side input / output: UTP, one Active F/O m/m - s/m WDM Fiber Link Port: s/m
CWM-2011-P85 100BASE-TX / FX Client Side input / output: UTP, one Passive F/O s/m WDM Fiber Link Port: s/m
CWM-2021-P 100BASE-FX / FX Client Side input / output: one Active m/m one Passive m/m WDM Fiber Link Port: m/m
CWM-2021-PSM 100BASE-FX / FX Client Side input / output: one Active m/m one Passive s/m WDM Fiber Link Port: s/m
CWM-2021-SM 100BASE-FX / FX Client Side input / output: two Active F/O m/m - s/m WDM Fiber Link Port: s/m
  back to top

***WAVEPLEX 2000 Gigabit, 2-Channel Wavelength Division Multiplexers {Media Converters}***

GWM-2001 1000BASE-T / SX Client Side input / output: UTP / UTP WDM Fiber Link Port: m/m
GWM-2001-SM 1000BASE-T / LX Client Side input / output: UTP / UTP WDM Fiber Link Port: s/m
GWM-2011-P 1000BASE-T / SX Client Side input / output: UTP, one Passive [pass-thru] F/O m/m WDM Fiber Link Port: m/m
GWM-2011-PSM 1000BASE-T / LX Client Side input / output: UTP, one Passive [pass-thru] F/O s/m WDM Fiber Link Port: s/m
GWM-2011-SM 1000BASE-T / LX Client Side input / output: UTP, one Active F/O m/m - s/m WDM Fiber Link Port: s/m
GWM-2021-P 1000BASE-SX / SX Client Side input / output: one Active m/m, one Passive m/m WDM Fiber Link Port: m/m
GWM-2021-PSM 1000BASE-SX / LX Client Side input / output: one Active m/m, one Passive s/m WDM Fiber Link Port: s/m
GWM-2021-SM 1000BASE-SX / LX Client Side input / output: two Active F/O m/m - s/m WDM Fiber Link Port: s/m
  back to top

***Canarynet 100 Fast Ethernet [MII] Transceivers***

CFX-1171 100BASE-FX / MII SC m/m, 2Km (MII ~ Medium Independent Interface)  
CFX-1173 100BASE-FX / MII ST m/m, 2Km  
CFX-1181-SM 100BASE-FX / MII SC s/m, 8Km  
CFX-1171-SM 100BASE-FX / MII SC s/m, 20Km  
CFX-1171-LSM 100BASE-FX / MII SC s/m, 40Km  
CTX-1170 100BASE-FX / MII RJ-45 UTP 100m  
  back to top

***10Mbs AUI Mini-Transceivers***

MTX-1070 10BASE-T / AUI Mini-UTP Transceiver 7 LEDs  
MBX-1020 10BASE-2 / AUI Mini-BNC Transceiver 2 LEDs  
MFX-1062 10BASE-FL / AUI Mini-F / O Transceiver 6 LEDs ST, m/m, 2Km  
MFX-1062-SM 10BASE-FL / AUI Mini-F / O Transceiver 6 LEDs ST, s/m, 15Km  
  back to top

***10Mbs Single Repeater Modules for Discontinued CMR-7020 Series Hubs***

SRM-1010 10BASE-5 Single Repeater Module with 1 AUI  
SRM-1020 10BASE-2 Single Repeater Module with 1 BNC  
SRM-1030 10BASE-T Single Repeater Module with 1 UTP  
SRM-1041 10BASE-FL Single Repeater Module with 1 F/O SC  
SRM-1042 10BASE-FL Single Repeater Module with 1 F/O ST  
SRM-1042-SM 10BASE-FL Single Repeater Module with 1 F/O ST, SM  
  back to top

Canary Combined Family of CWDM Passive Mux/Demux / OADMs and Active CWDM Converters [from all Product categories]

  

***Canary Rackable/Standalone, Passive (SC) CWDM, MUX/DEMUX Chassis**

CR-4MD1-A [4] Mux/Demx, s/m SC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CR-4MD1-B [4] Mux/Demx, s/m SC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CR-4MD1-C [4] Mux/Demx, s/m SC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CR-4MD1-D [4] Mux/Demx, s/m SC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CR-4MD1-M [4] Mux/Demx, s/m SC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CR-8MD1-E [8] Mux/Demx, s/m SC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, SC,
CR-8MD1-F [8] Mux/Demx, s/m SC Group-C+D ls:1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CR-8MD1-M [8] Mux/Demx, s/m SC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm  
CR-12MD1-G [12] Mux/Demx, s/m SC Group-E ls, Plus C ls : 1290, 1310, 1330, 1350 hm NW Port: s/m, SC,
CR-12MD1-H [12] Mux/Demx, s/m SC Group-E ls, Plus D ls : 1390, 1410, 1430, 1450 hm  
CR-12MD1-M [12] Mux/Demx, s/m SC Group-E ls, Plus C ls: 1310, 1330, 1350, + 1370 hm (Group-D)  
CR-16MD1-J [16] Mux/Demx, s/m SC J = Combined l Groups: Group-E ls + Group-F ls NW Port: s/m, SC,
CR-18MD1-K [18] Mux/Demx, s/m SC K = Combined Groups: Group-E ls + Group-F ls + 1270, 1370 hm NW Port: s/m, SC,
 back to top

***Canary Rackable/Standalone, Passive (LC) CWDM, MUX/DEMUX Chassis**

CR-4MD6-A [4] Mux/Demx, s/m LC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CR-4MD6-B [4] Mux/Demx, s/m LC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CR-4MD6-C [4] Mux/Demx, s/m LC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CR-4MD6-D [4] Mux/Demx, s/m LC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CR-4MD6-M [4] Mux/Demx, s/m LC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CR-8MD6-E [8] Mux/Demx, s/m LC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, SC,
CR-8MD6-F [8] Mux/Demx, s/m LC Group-C+D ls: 1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CR-8MD6-M [8] Mux/Demx, s/m LC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CR-12MD6-G [12] Mux/Demx, s/m LC Group-E ls, Plus C ls : 1290, 1310, 1330, 1350 hm NW Port: s/m, SC,
CR-12MD6-H [12] Mux/Demx, s/m LC Group-E ls, Plus D ls : 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CR-12MD6-M [12] Mux/Demx, s/m LC Group-E ls, Plus C ls: 1310, 1330, 1350, + 1370 hm (Group-D) NW Port: s/m, SC,
CR-16MD6-J [16] Mux/Demx, s/m LC J = Combined l Groups: Group-E ls + Group-F ls NW Port: s/m, SC,
CR-18MD6-K [18] Mux/Demx, s/m LC K = Combined Groups: Group-E ls + Group-F ls + 1270, 1370 hm NW Port: s/m, SC,
  back to top

***Canary Rackable/Standalone, Passive CWDM, (SC Client) Optical Add Drop Multiplexers [OADM] **

Group-A ls One Channel > [1] l Drop    
AD1-47-S1 1-chan 1l, [1] SC Client port Group-A l: 1470 hm NW Ports: [2] s/m, SC,
AD1-51-S1 1-chan 1l, [1] SC Client port Group-A l: 1510 hm NW Ports: [2] s/m, SC,
AD1-55-S1 1-chan 1l, [1] SC Client port Group-A l: 1550 hm NW Ports: [2] s/m, SC,
AD1-59-S1 1-chan 1l, [1] SC Client port Group-A l: 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD1-49-S1 1-chan 1l, [1] SC Client port Group-B l: 1490 hm NW Ports: [2] s/m, SC,
AD1-53-S1 1-chan 1l, [1] SC Client port Group-B l: 1530 hm NW Ports: [2] s/m, SC,
AD1-57-S1 1-chan 1l, [1] SC Client port Group-B l: 1570 hm NW Ports: [2] s/m, SC,
AD1-61-S1 1-chan 1l, [1] SC Client port Group-B l: 1610 hm NW Ports: [2] s/m, SC,
       
Group-C ls One Channel > [1] l Drop    
AD1-27-S1 1-chan 1l [1] SC Client port Group-C l: 1270 hm NW Ports: [2] s/m, SC,
AD1-29-S1 1-chan 1l [1] SC Client port Group-C l: 1290 hm NW Ports: [2] s/m, SC,
AD1-31-S1 1-chan 1l [1] SC Client port Group-C l: 1310 hm NW Ports: [2] s/m, SC,
AD1-33-S1 1-chan 1l [1] SC Client port Group-C l: 1330 hm NW Ports: [2] s/m, SC,
AD1-35-S1 1-chan 1l [1] SC Client port Group-C l: 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD1-37-S1 1-chan 1l [2] SC Client port Group-D l: 1370 hm NW Ports: [2] s/m, SC,
AD1-39-S1 1-chan 1l [2] SC Client port Group-D l: 1390 hm NW Ports: [2] s/m, SC,
AD1-41-S1 1-chan 1l [2] SC Client port Group-D l: 1410 hm NW Ports: [2] s/m, SC,
AD1-43-S1 1-chan 1l [2] SC Client port Group-D l: 1430 hm NW Ports: [2] s/m, SC,
AD1-45-S1 1-chan 1l [2] SC Client port Group-D l: 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Two Channels > [1] l Drop    
AD2-47-S1 2-chan 1l [2] SC Client ports Group-A l: 1470 hm NW Ports: [2] s/m, SC,
AD2-51-S1 2-chan 1l [2] SC Client ports Group-A l: 1510 hm NW Ports: [2] s/m, SC,
AD2-55-S1 2-chan 1l [2] SC Client ports Group-A l: 1550 hm NW Ports: [2] s/m, SC,
AD2-59-S1 2-chan 1l [2] SC Client ports Group-A l: 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD2-49-S1 2-chan 1l [2] SC Client ports Group-B l: 1490 hm NW Ports: [2] s/m, SC,
AD2-53-S1 2-chan 1l [2] SC Client ports Group-B l: 1530 hm NW Ports: [2] s/m, SC,
AD2-57-S1 2-chan 1l [2] SC Client ports Group-B l: 1570 hm NW Ports: [2] s/m, SC,
AD2-61-S1 2-chan 1l [2] SC Client ports Group-B l: 1610 hm NW Ports: [2] s/m, SC,
Group-C ls Two Channels > [1] l Drop    
AD2-27-S1 2-chan 1l [2] SC Client ports Group-C l: 1270 hm NW Ports: [2] s/m, SC,
AD2-29-S1 2-chan 1l [2] SC Client ports Group-C l: 1290 hm NW Ports: [2] s/m, SC,
AD2-31-S1 2-chan 1l [2] SC Client ports Group-C l: 1310 hm NW Ports: [2] s/m, SC,
AD2-33-S1 2-chan 1l [2] SC Client ports Group-C l: 1330 hm NW Ports: [2] s/m, SC,
AD2-35-S1 2-chan 1l [2] SC Client ports Group-C l: 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD2-37-S1 2-chan 1l [2] SC Client ports Group-D l: 1370 hm NW Ports: [2] s/m, SC,
AD2-39-S1 2-chan 1l [2] SC Client ports Group-D l: 1390 hm NW Ports: [2] s/m, SC,
AD2-41-S1 2-chan 1l [2] SC Client ports Group-D l: 1410 hm NW Ports: [2] s/m, SC,
AD2-43-S1 2-chan 1l [2] SC Client ports Group-D l: 1430 hm NW Ports: [2] s/m, SC,
AD2-45-S1 2-chan 1l [2] SC Client ports Group-D l: 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Two Channels > [2] l Drops    
AD2-4751-S1 2-chan 2l [2] SC Client ports Group-A ls: 1470 hm, 1510 hm NW Ports: [2] s/m, SC,
AD2-5559-S1 2-chan 2l [2] SC Client ports Group-A ls: 1550 hm, 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD2-4953-S1 2-chan 2l [2] SC Client ports Group-B ls: 1490 hm, 1530 hm NW Ports: [2] s/m, SC,
AD2-5761-S1 2-chan 2l [2] SC Client ports Group-B ls: 1570 hm, 1610 hm NW Ports: [2] s/m, SC,
Group-C ls      
AD2-2933-S1 2-chan 2l [2] SC Client ports Group-C ls: 1290 hm, 1330 hm NW Ports: [2] s/m, SC,
AD2-3135-S1 2-chan 2l [2] SC Client ports Group-C ls: 1310 hm, 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD2-3943-S1 2-chan 2l [2] SC Client ports Group-D ls: 1390 hm, 1430 hm NW Ports: [2] s/m, SC,
AD2-4145-S1 2-chan 2l [2] SC Client ports Group-D ls: 1410 hm, 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Four Channels > [4] l Drops    
AD4-4A-S1 4-chan 4l [4] SC Client ports Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD4-4B-S1 4-chan 4l [4] SC Client ports Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Ports: [2] s/m, SC,
Group-C ls      
AD4-4C-S1 4-chan 4l [4] SC Client ports Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD4-4D-S1 4-chan 4l [4] SC Client ports Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Ports: [2] s/m, SC,
AD4-4M-S1 4-chan 4l [4] SC Client ports Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm, NW Ports: [2] s/m, SC,
  back to top

***Canary Rackable/Standalone, Passive CWDM, (LC Client) Optical Add Drop Multiplexers [OADM] **

Group-A ls One Channel > [1] l Drop    
AD1-47-S6 1-chan 1l, [1] LC Client port Group-A l: 1470 hm NW Ports: [2] s/m, SC,
AD1-51-S6 1-chan 1l, [1] LC Client port Group-A l: 1510 hm NW Ports: [2] s/m, SC,
AD1-55-S6 1-chan 1l, [1] LC Client port Group-A l: 1550 hm NW Ports: [2] s/m, SC,
AD1-59-S6 1-chan 1l, [1] LC Client port Group-A l: 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD1-49-S6 1-chan 1l, [1] LC Client port Group-B l: 1490 hm NW Ports: [2] s/m, SC,
AD1-53-S6 1-chan 1l, [1] LC Client port Group-B l: 1530 hm NW Ports: [2] s/m, SC,
AD1-57-S6 1-chan 1l, [1] LC Client port Group-B l: 1570 hm NW Ports: [2] s/m, SC,
AD1-61-S6 1-chan 1l, [1] LC Client port Group-B l: 610 hm NW Ports: [2] s/m, SC,
       
Group-C ls One Channel > [1] l Drop    
AD1-27-S6 1-chan 1l, [1] LC Client port Group-C l: 1270 hm NW Ports: [2] s/m, SC,
AD1-29-S6 1-chan 1l, [1] LC Client port Group-C l: 1290 hm NW Ports: [2] s/m, SC,
AD1-31-S6 1-chan 1l, [1] LC Client port Group-C l: 1310 hm NW Ports: [2] s/m, SC,
AD1-33-S6 1-chan 1l, [1] LC Client port Group-C l: 1330 hm NW Ports: [2] s/m, SC,
AD1-35-S6 1-chan 1l, [1] LC Client port Group-C l: 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD1-37-S6 1-chan 1l, [1] LC Client port Group-D l: 1370 hm NW Ports: [2] s/m, SC,
AD1-39-S6 1-chan 1l, [1] LC Client port Group-D l: 1390 hm NW Ports: [2] s/m, SC,
AD1-41-S6 1-chan 1l, [1] LC Client port Group-D l: 1410 hm NW Ports: [2] s/m, SC,
AD1-43-S6 1-chan 1l, [1] LC Client port Group-D l: 1430 hm NW Ports: [2] s/m, SC,
AD1-45-S6 1-chan 1l, [1] LC Client port Group-D l: 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Two Channels > [1] l Drop    
AD2-47-S6 2-chan 1l [2] LC Client ports Group-A l: 1470 hm NW Ports: [2] s/m, SC,
AD2-51-S6 2-chan 1l [2] LC Client ports Group-A l: 1510 hm NW Ports: [2] s/m, SC,
AD2-55-S6 2-chan 1l [2] LC Client ports Group-A l: 1550 hm NW Ports: [2] s/m, SC,
AD2-59-S6 2-chan 1l [2] LC Client ports Group-A l: 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD2-49-S6 2-chan 1l [2] LC Client ports Group-B l: 1490 hm NW Ports: [2] s/m, SC,
AD2-53-S6 2-chan 1l [2] LC Client ports Group-B l: 1530 hm NW Ports: [2] s/m, SC,
AD2-57-S6 2-chan 1l [2] LC Client ports Group-B l: 1570 hm NW Ports: [2] s/m, SC,
AD2-61-S6 2-chan 1l [2] LC Client ports Group-B l: 1610 hm NW Ports: [2] s/m, SC,
Group-C ls Two Channels > [1] l Drop    
AD2-27-S6 2-chan 1l [2] LC Client ports Group-C l: 1270 hm NW Ports: [2] s/m, SC,
AD2-29-S6 2-chan 1l [2] LC Client ports Group-C l: 1290 hm NW Ports: [2] s/m, SC,
AD2-31-S6 2-chan 1l [2] LC Client ports Group-C l: 1310 hm NW Ports: [2] s/m, SC,
AD2-33-S6 2-chan 1l [2] LC Client ports Group-C l: 1330 hm NW Ports: [2] s/m, SC,
AD2-35-S6 2-chan 1l [2] LC Client ports Group-C l: 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD2-37-S6 2-chan 1l [2] LC Client ports Group-D l: 1370 hm NW Ports: [2] s/m, SC,
AD2-39-S6 2-chan 1l [2] LC Client ports Group-D l: 1390 hm NW Ports: [2] s/m, SC,
AD2-41-S6 2-chan 1l [2] LC Client ports Group-D l: 1410 hm NW Ports: [2] s/m, SC,
AD2-43-S6 2-chan 1l [2] LC Client ports Group-D l: 1430 hm NW Ports: [2] s/m, SC,
AD2-45-S6 2-chan 1l [2] LC Client ports Group-D l: 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Two Channels > [2] l Drops    
AD2-4751-S6 2-chan 2l [2] LC Client ports Group-A ls: 1470 hm, 1510 hm NW Ports: [2] s/m, SC,
AD2-5559-S6 2-chan 2l [2] LC Client ports Group-A ls: 1550 hm, 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD2-4953-S6 2-chan 2l [2] LC Client ports Group-B ls: 1490 hm, 1530 hm NW Ports: [2] s/m, SC,
AD2-5761-S6 2-chan 2l [2] LC Client ports Group-B ls: 1570 hm, 1610 hm NW Ports: [2] s/m, SC,
Group-C ls      
AD2-2933-S6 2-chan 2l [2] LC Client ports Group-C ls: 1290 hm, 1330 hm NW Ports: [2] s/m, SC,
AD2-3135-S6 2-chan 2l [2] LC Client ports Group-C ls: 1310 hm, 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD2-3943-S6 2-chan 2l [2] LC Client ports Group-D ls: 1390 hm, 1430 hm NW Ports: [2] s/m, SC,
AD2-4145-S6 2-chan 2l [2] LC Client ports Group-D ls: 1410 hm, 1450 hm NW Ports: [2] s/m, SC,
       
Group-A ls Four Channels > [4] l Drops    
AD4-4A-S6 4-chan 4l [4] LC Client ports Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Ports: [2] s/m, SC,
Group-B ls      
AD4-4B-S6 4-chan 4l [4] LC Client ports Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Ports: [2] s/m, SC,
Group-C ls      
AD4-4C-S6 4-chan 4l [4] LC Client ports Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Ports: [2] s/m, SC,
Group-D ls      
AD4-4D-S6 4-chan 4l [4] LC Client ports Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Ports: [2] s/m, SC,
AD4-4M-S6 4-chan 4l [4] LC Client ports Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm, NW Ports: [2] s/m, SC,
  back to top

*** Active CWDM, Gigabit, UTP to Fiber, Standalone Converters**

GFT-10W-27 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: RJ-45
GFT-10W-29 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: RJ-45
GFT-10W-31 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: RJ-45
GFT-10W-33 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: RJ-45
GFT-10W-35 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: RJ-45
GFT-10W-37 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: RJ-45
GFT-10W-39 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: RJ-45
GFT-10W-41 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: RJ-45
GFT-10W-43 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: RJ-45
GFT-10W-45 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: RJ-45
GFT-10W-47 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: RJ-45
GFT-10W-49 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: RJ-45
GFT-10W-51 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: RJ-45
GFT-10W-53 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: RJ-45
GFT-10W-55 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: RJ-45
GFT-10W-57 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: RJ-45
GFT-10W-59 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: RJ-45
GFT-10W-61 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. GFT-10W-27E5 [50Km] or E8 [80Km]  
  back to top

***Active CWDM, Gigabit Fiber to Fiber, Standalone Converters**

GFC-55W-27 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m SC, 550m
GFC-55W-29 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m SC, 550m
GFC-55W-31 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m SC, 550m
GFC-55W-33 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m SC, 550m
GFC-55W-35 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m SC, 550m
GFC-55W-37 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m SC, 550m
GFC-55W-39 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m SC, 550m
GFC-55W-41 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m SC, 550m
GFC-55W-43 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m SC, 550m
GFC-55W-45 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m SC, 550m
GFC-55W-47 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m SC, 550m
GFC-55W-49 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m SC, 550m
GFC-55W-51 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m SC, 550m
GFC-55W-53 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m SC, 550m
GFC-55W-55 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m SC, 550m
GFC-55W-57 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m SC, 550m
GFC-55W-59 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m SC, 550m
GFC-55W-61 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m SC, 550m
    * Extended Reach Versions available e.g. GFC-55W-27E5 [50Km] or E8 [80Km]  
  back to top

***Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Standalone Converters**

  Fixed 1.0625 Gigabaud    
FC-155W-27 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m, SC, 550m
FC-155W-29 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m, SC, 550m
FC-155W-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m, SC, 550m
FC-155W-33 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m, SC, 550m
FC-155W-35 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m, SC, 550m
       
FC-155W-37 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m, SC, 550m
FC-155W-39 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m, SC, 550m
FC-155W-41 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m, SC, 550m
FC-155W-43 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m, SC, 550m
FC-155W-45 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m, SC, 550m
FC-155W-47 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m, SC, 550m
FC-155W-49 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m, SC, 550m
FC-155W-51 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m, SC, 550m
FC-155W-53 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m, SC, 550m
FC-155W-55 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m, SC, 550m
FC-155W-57 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m, SC, 550m
FC-155W-59 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m, SC, 550m
FC-155W-61 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m, SC, 550m
    * Extended Reach Versions available e.g. FT-155W-27E5 [50Km] or E8 [80Km]  
  back to top

***Active CWDM, 100 Mb, UTP to Fiber, Standalone Converters**

CFT-20W-27 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: RJ-45
CFT-20W-29 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: RJ-45
CFT-20W-31 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: RJ-45
CFT-20W-33 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: RJ-45
CFT-20W-35 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: RJ-45
CFT-20W-37 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: RJ-45
CFT-20W-39 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: RJ-45
CFT-20W-41 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: RJ-45
CFT-20W-43 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: RJ-45
CFT-20W-45 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: RJ-45
CFT-20W-47 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: RJ-45
CFT-20W-49 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: RJ-45
CFT-20W-51 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: RJ-45
CFT-20W-53 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: RJ-45
CFT-20W-55 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: RJ-45
CFT-20W-57 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: RJ-45
CFT-20W-59 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: RJ-45
CFT-20W-61 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CFT-20W-27E8 [80 Km]  
  back to top

***Active CWDM, 100 Mb, Fiber to Fiber, Standalone Converters**

CFC-91W-27 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: m/m, SC, 2Km
CFC-91W-29 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: m/m, SC, 2Km
CFC-91W-31 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: m/m, SC, 2Km
CFC-91W-33 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: m/m, SC, 2Km
CFC-91W-35 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: m/m, SC, 2Km
CFC-91W-37 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: m/m, SC, 2Km
CFC-91W-39 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: m/m, SC, 2Km
CFC-91W-41 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: m/m, SC, 2Km
CFC-91W-43 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: m/m, SC, 2Km
CFC-91W-45 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: m/m, SC, 2Km
CFC-91W-47 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: m/m, SC, 2Km
CFC-9W-49 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: m/m, SC, 2Km
       
CFC-91W-51 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: m/m, SC, 2Km
CFC-91W-53 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: m/m, SC, 2Km
CFC-91W-55 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: m/m, SC, 2Km
CFC-91W-57 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: m/m, SC, 2Km
CFC-91W-59 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: m/m, SC, 2Km
CFC-91W-61 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: m/m, SC, 2Km
    * Extended Reach Versions available e.g. CFC-91W-27E8 [80Km]  
  back to top

***CCN-2000 Chassis, Passive CWDM, MUX/DEMUX Modules**

CN-4MD6-A [4] Mux/Demx, s/m LC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CN-4MD6-B [4] Mux/Demx, s/m LC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CN-4MD6-C [4] Mux/Demx, s/m LC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CN-4MD6-D [4] Mux/Demx, s/m LC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CN-4MD6-M [4] Mux/Demx, s/m LC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CN-8MD6-E [8] Mux/Demx, s/m LC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, SC,
CN-8MD6-F [8] Mux/Demx, s/m LC Group-C+D ls:1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-8MD6-M [8] Mux/Demx, s/m LC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-12MD6-G [12] Mux/Demx, s/m LC Group-E ls, Plus C ls : 1290, 1310, 1330, 1350 hm NW Port: s/m, SC,
CN-12MD6-H [12] Mux/Demx, s/m LC Group-E ls, Plus D ls : 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CN-12MD6-M [12] Mux/Demx, s/m LC Group-E ls, Plus C ls: 1310, 1330, 1350, + 1370 hm (Group-D) NW Port: s/m, SC,
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Gigabit UTP to Fiber, Converter Modules**

CN-10W-27 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: RJ-45
CN-10W-29 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: RJ-45
CN-10W-31 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: RJ-45
CN-10W-33 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: RJ-45
CN-10W-35 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: RJ-45
CN-10W-37 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: RJ-45
CN-10W-39 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: RJ-45
CN-10W-41 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: RJ-45
CN-10W-43 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: RJ-45
CN-10W-45 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: RJ-45
       
CN-10W-47 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: RJ-45
CN-10W-49 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: RJ-45
CN-10W-51 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: RJ-45
CN-10W-53 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: RJ-45
CN-10W-55 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: RJ-45
CN-10W-57 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: RJ-45
CN-10W-59 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: RJ-45
CN-10W-61 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CN-10W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules**

CN-55W-27 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m SC, 550m
CN-55W-29 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m SC, 550m
CN-55W-31 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m SC, 550m
CN-55W-33 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m SC, 550m
CN-55W-35 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m SC, 550m
CN-55W-37 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m SC, 550m
CN-55W-39 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m SC, 550m
CN-55W-41 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m SC, 550m
CN-55W-43 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m SC, 550m
CN-55W-45 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m SC, 550m
CN-55W-47 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m SC, 550m
CN-55W-49 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m SC, 550m
CN-55W-51 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m SC, 550m
CN-55W-53 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m SC, 550m
CN-55W-55 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m SC, 550m
CN-55W-57 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m SC, 550m
CN-55W-59 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m SC, 550m
CN-55W-61 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m SC, 550m
    * Extended Reach Versions available e.g. CN-55W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 1.0625 Gigabaud    
CN-155W-27 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m, SC, 550m
CN-155W-29 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m, SC, 550m
CN-155W-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m, SC, 550m
CN-155W-33 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m, SC, 550m
CN-155W-35 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m, SC, 550m
CN-155W-37 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m, SC, 550m
CN-155W-39 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m, SC, 550m
CN-155W-41 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m, SC, 550m
CN-155W-43 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m, SC, 550m
CN-155W-45 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m, SC, 550m
CN-155W-47 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m, SC, 550m
CN-155W-49 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m, SC, 550m
CN-155W-51 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m, SC, 550m
CN-155W-53 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m, SC, 550m
CN-155W-55 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m, SC, 550m
CN-155W-57 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m, SC, 550m
CN-155W-59 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m, SC, 550m
CN-155W-61 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m, SC, 550m
    * Extended Reach Versions available e.g. CN-155W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, Fibre Channel, Fixed 2.125 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 2.125 Gigabaud    
CN-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CN-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, UTP to Fiber, Converter Modules**

CN-20W-27 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: RJ-45
CN-20W-29 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: RJ-45
CN-20W-31 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: RJ-45
CN-20W-33 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: RJ-45
CN-20W-35 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: RJ-45
CN-20W-37 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: RJ-45
CN-20W-39 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: RJ-45
CN-20W-41 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: RJ-45
CN-20W-43 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: RJ-45
CN-20W-45 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: RJ-45
CN-20W-47 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: RJ-45
CN-20W-49 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: RJ-45
CN-20W-51 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: RJ-45
CN-20W-53 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: RJ-45
CN-20W-55 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: RJ-45
CN-20W-57 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: RJ-45
CN-20W-59 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: RJ-45
CN-20W-61 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CN-20W-27E8 [80Km]  
  back to top

***CCN-2000 / 0400 Chassis, Active CWDM, 100Mb, Fiber to Fiber, Converter Modules**

CN-C11W-27 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: m/m, SC, 2Km
CN-C11W-29 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: m/m, SC, 2Km
CN-C11W-31 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: m/m, SC, 2Km
CN-C11W-33 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: m/m, SC, 2Km
CN-C11W-35 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: m/m, SC, 2Km
CN-C11W-37 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: m/m, SC, 2Km
CN-C11W-39 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: m/m, SC, 2Km
CN-C11W-41 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: m/m, SC, 2Km
CN-C11W-43 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: m/m, SC, 2Km
CN-C11W-45 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: m/m, SC, 2Km
CN-C11W-47 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: m/m, SC, 2Km
CN-C11W-49 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: m/m, SC, 2Km
CN-C11W-51 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: m/m, SC, 2Km
CN-C11W-53 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: m/m, SC, 2Km
CN-C11W-55 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: m/m, SC, 2Km
CN-C11W-57 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: m/m, SC, 2Km
CN-C11W-59 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: m/m, SC, 2Km
CN-C11W-61 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: m/m, SC, 2Km
    * Extended Reach Versions available e.g. CN-C11W-27E8 [80Km]  
  back to top

***CCM-1600 Chassis, Passive CWDM, MUX/DEMUX Modules**

CM-4MD6-A [4] Mux/Demx, s/m LC Group-A ls: 1470 hm, 1510 hm, 1550 hm, 1590 hm NW Port: s/m, SC,
CM-4MD6-B [4] Mux/Demx, s/m LC Group-B ls: 1490 hm, 1530 hm, 1570 hm, 1610 hm NW Port: s/m, SC,
CM-4MD6-C [4] Mux/Demx, s/m LC Group-C ls: 1290 hm, 1310 hm, 1330 hm, 1350 hm NW Port: s/m, SC,
CM-4MD6-D [4] Mux/Demx, s/m LC Group-D ls: 1390 hm, 1410 hm, 1430 hm, 1450 hm NW Port: s/m, SC,
CM-4MD6-M [4] Mux/Demx, s/m LC Group-C ls: 1310 hm, 1330 hm, 1350 hm, + 1370 hm (Group-D) NW Port: s/m, SC,
CM-8MD6-E [8] Mux/Demx, s/m LC Group-E ls: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 hm NW Port: s/m, SC,
CM-8MD6-F [8] Mux/Demx, s/m LC Group-C+D ls:1290, 1310, 1330, 1350, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
CM-8MD6-M [8] Mux/Demx, s/m LC Group-M ls: 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450 hm NW Port: s/m, SC,
  back to top

***CCM-1600 Chassis, Active CWDM, Gigabit, UTP to Fiber, Converter Modules**

CM-10W-27 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: RJ-45
CM-10W-29 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: RJ-45
CM-10W-31 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: RJ-45
CM-10W-33 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: RJ-45
CM-10W-35 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: RJ-45
CM-10W-37 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: RJ-45
CM-10W-39 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: RJ-45
CM-10W-41 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: RJ-45
CM-10W-43 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: RJ-45
CM-10W-45 1000BASE-T / LX Port 1: s/m, SC, 40Km * ll = 1450 hm Port 2: RJ-45
CM-10W-47 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: RJ-45
CM-10W-49 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: RJ-45
CM-10W-51 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: RJ-45
CM-10W-53 1000BASE-T / LX Port 1: s/m, SC, 40Km * ll = 1530 hm Port 2: RJ-45
CM-10W-55 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: RJ-45
CM-10W-57 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: RJ-45
CM-10W-59 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: RJ-45
CM-10W-61 1000BASE-T / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CM-10W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Gigabit Fiber to Fiber, Converter Modules**

CM-55W-27 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m SC, 550m
CM-55W-29 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m SC, 550m
CM-55W-31 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m SC, 550m
CM-55W-33 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m SC, 550m
CM-55W-35 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m SC, 550m
CM-55W-37 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m SC, 550m
CM-55W-39 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m SC, 550m
CM-55W-41 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m SC, 550m
CM-55W-43 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m SC, 550m
CM-55W-45 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m SC, 550m
CM-55W-47 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m SC, 550m
CM-55W-49 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m SC, 550m
CM-55W-51 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m SC, 550m
CM-55W-53 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m SC, 550m
CM-55W-55 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m SC, 550m
CM-55W-57 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m SC, 550m
CM-55W-59 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m SC, 550m
CM-55W-61 1000BASE-SX / LX Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m SC, 550m
    * Extended Reach Versions available e.g. CM-55W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 1.0625 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 1.0625 Gigabaud    
CM-155W-27 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1270 hm Port 2: m/m, SC, 550m
CM-155W-29 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1290 hm Port 2: m/m, SC, 550m
CM-155W-31 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1310 hm Port 2: m/m, SC, 550m
CM-155W-33 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1330 hm Port 2: m/m, SC, 550m
CM-155W-35 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1350 hm Port 2: m/m, SC, 550m
CM-155W-37 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1370 hm Port 2: m/m, SC, 550m
CM-155W-39 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1390 hm Port 2: m/m, SC, 550m
CM-155W-41 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1410 hm Port 2: m/m, SC, 550m
CM-155W-43 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1430 hm Port 2: m/m, SC, 550m
CM-155W-45 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1450 hm Port 2: m/m, SC, 550m
CM-155W-47 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1470 hm Port 2: m/m, SC, 550m
CM-155W-49 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1490 hm Port 2: m/m, SC, 550m
CM-155W-51 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1510 hm Port 2: m/m, SC, 550m
CM-155W-53 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1530 hm Port 2: m/m, SC, 550m
CM-155W-55 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1550 hm Port 2: m/m, SC, 550m
CM-155W-57 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1570 hm Port 2: m/m, SC, 550m
CM-155W-59 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1590 hm Port 2: m/m, SC, 550m
CM-155W-61 ANSI X3T1 FC-AL Port 1: s/m, SC, 40Km * l = 1610 hm Port 2: m/m, SC, 550m
    * Extended Reach Versions available e.g. CM-155W-27E5 [50Km] or E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, Fibre Channel, Fixed 2.125 Gigabaud, Fiber to Fiber, Converter Modules**

  Fixed 2.125 Gigabaud    
CM-256-GBC ANSI X3T1 FC-AL Port 1: GBIC Slot, GBIC = SC, multiple ls and Transmit Distances Port 2: m/m, LC, 550m
CM-256-SFP ANSI X3T1 FC-AL Port 1: SFP Slot, SFP = LC, multiple ls and Transmit Distances Port 2: s/m, LC, 550m
  back to top

***CCM-1600 Chassis, Active CWDM, 100 Mb, UTP to Fiber, Converter Modules**

CM-12W-27 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: RJ-45
CM-12W-29 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: RJ-45
CM-12W-31 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: RJ-45
CM-12W-33 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: RJ-45
CM-12W-35 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: RJ-45
CM-12W-37 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: RJ-45
CM-12W-39 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: RJ-45
CM-12W-41 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: RJ-45
CM-12W-43 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: RJ-45
CM-12W-45 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: RJ-45
CM-12W-47 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: RJ-45
CM-12W-49 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: RJ-45
CM-12W-51 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: RJ-45
CM-12W-53 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: RJ-45
CM-12W-55 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: RJ-45
CM-12W-57 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: RJ-45
CM-12W-59 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: RJ-45
CM-12W-61 100BASE-TX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: RJ-45
    * Extended Reach Versions available e.g. CM-12W-27E8 [80Km]  
  back to top

***CCM-1600 Chassis, Active CWDM, 100 Mb, Fiber to Fiber, Converter Modules**

CM-91W-27 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1270 hm Port 2: m/m, SC, 2Km
CM-91W-29 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1290 hm Port 2: m/m, SC, 2Km
CM-91W-31 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1310 hm Port 2: m/m, SC, 2Km
CM-91W-33 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1330 hm Port 2: m/m, SC, 2Km
CM-91W-35 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1350 hm Port 2: m/m, SC, 2Km
CM-91W-37 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1370 hm Port 2: m/m, SC, 2Km
CM-91W-39 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1390 hm Port 2: m/m, SC, 2Km
CM-91W-41 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1410 hm Port 2: m/m, SC, 2Km
CM-91W-43 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1430 hm Port 2: m/m, SC, 2Km
CM-91W-45 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1450 hm Port 2: m/m, SC, 2Km
CM-91W-47 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1470 hm Port 2: m/m, SC, 2Km
CM-91W-49 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1490 hm Port 2: m/m, SC, 2Km
CM-91W-51 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1510 hm Port 2: m/m, SC, 2Km
CM-91W-53 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1530 hm Port 2: m/m, SC, 2Km
CM-91W-55 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1550 hm Port 2: m/m, SC, 2Km
CM-91W-57 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1570 hm Port 2: m/m, SC, 2Km
CM-91W-59 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1590 hm Port 2: m/m, SC, 2Km
CM-91W-61 100BASE-FX / FX Port 1: s/m, SC, 50Km l = 1610 hm Port 2: m/m, SC, 2Km
    * Extended Reach Versions available e.g. CM-91W-27E8 [80Km]  
  back to top


Home | News | Products | About Canary | Careers | Contact


Copyright 1997-2010 Canary Communications
All trademarks and registered trademarks are the properties of their respective companies.
Please contact the Canary Communications Webmaster with any comments or suggestions about this web site.